- Thermal Protection -
▪ The power supply shall go into thermal protection as the case temperature exceeds 86ºC(±5ºC)limit. 
▪ The output shall recover only when the temperature becomes normal and AC power is turned on again
▪ Protections
Over Power: 110% ~ 150% MAX.
Over Voltage: +3.3V→3.7V~4.1V ,+5V→5.7V~6.5V,+12V→13.2V~14.4V
Short Circuit: Shutdown And Latch Re-power ON
▪ Function
Power Good Signal: Delay 200ms~500ms, TTL compatible signal
Power Fail Delay: >1msec. ,TTL compatible signal
PS-ON: Power off: PS-ON = 2V min.; Power on: PS-ON = 0.8V max.
TTL Signal: Normal(Power Supply On): Output Condition =3V Min. , 5.25VMax. 
Failure(Power Supply Off): Output Condition =0V Min. ,1VMax.
Current Sharing: ON +3.3V,+5V,+12V
▪ Environmental
Operating Temperature: 0°C to 50°C
Storage Temperature: -20°C to +80°C
Operating Humidity: 20% to 90%,non-condensing
Storage Humidity: 5% to 95%,non-condensing
▪ Safety & EMI/RFI
Safety Standards: TO MEET CUL UL, TUV
Withstand Voltage: I/P-O/P:1.5KVAC FOR 1 minute. I/P-FG:1.5KVAC For 1 minute
Isolation Resistance: I/P-O/P,I/P-FG,O/P-FG: 500VDC , 50M ohms min.
▪ Others
MTBF: Using MIL - HDBK -217F the calculated MTBF >100,000 hours at 25°C
Coolings: 40x40x20mm x 2pcs DC fans
Dimension(D x W x H): 260(D)X106(W)x41.5(H)mm
| Output Voltage | Min. load | Max. load | Regulation LOAD LINE | Output Ripple & Noise Max.(p-p)
 | 
| +5V | 1A | 20A | 5% | 1% | 60mV | 
| +3.3V | 1A | 20A | 5% | 1% | 60mV | 
| +12V | 2A | 24A | 5% | 1% | 120mV | 
| -12V | 0A | 0.5A | 5% | 1% | 120mV | 
| +5VSB | 0.5A | 2A | 5% | 1% | 60mV | 
▪ Efficiency: 75% Typical at full load.
▪ Hold up Time: 1m sec Min. AT Full Load.
▪ Rated Power: 1.+5V&+3.3V TOTAL OUTPUT MAX.:150W; 
2.Power module Total output power not exceed 300W
| 20+4 Pin  | P4 MB  | Peripheral | FDD | 8-Pin | SATA | 
| X 1  | X 1  | X 5  | X 1  | X 1  | X 3  |